| Energy saving windows The company Adpol, meeting the market expectations, developed and included in its offer new products that meet the requirements for energy performance certificates
ADPOL 68
- K coefficient for a whole window from 1.1 W/m2K to 1.35 W/m2K
• ADPOL-68 system,
• frame/sash of wooden construction: Pine, Red Meranti , Eucalyptus,
• windowpane Ug = 0.7 of construction 4T/12Ar/4/12Ar/4T; windowpane packet up to 36mm (all constructions possible); swisspacer spacer; different windowpane packet can be used, f.e., P4, however Ug for such pane should be verified and a sash weight calculated, so the maximum acceptable weight is not exceeded,
• ALURON aluminium drip edge,
• TPE single sealing strip,
• that allows obtaining the K coefficient for the whole window below 1.35 - from 1.1 W/(m2xK) to 1.35 W/(m2xK), depending on the window size and type of wood,
ADPOL 78 TERMO
- K coefficient for a whole window below 1.0 W/m2K
• ADPOL 78 system,
• frame/sash of wooden construction: Pine, Red Meranti , Eucalyptus
• windowpane Ug = 0.6 of construction 4T/16Ar/4/14Ar/4T; windowpane packet up to 42mm – limited by the sash weight that cannot exceed a bearing capacity of fittings, swisspacer spacer,
• ALURON aluminium drip edge –new type (balcony and window frame has the same drip edge),
• TPE sealing strip and sash rabbets,
• that allows obtaining the K coefficient for the whole window below 1.0 - from 0.8 W/(m2xK) to 1.0 W/(m2xK), depending on the window size and type of wood
• aluminium threshold for balconies and HS terrace doors will not meet thermal requirements,
EKO 68 PASSIV
- K coefficient for a whole window below 0.8 W/m2K
• ADPOL EKO 68 PASSIV system,
• frame/sash of wood and aluminium construction, with thermal barrier,
• trims from the company BUG, welded in the corners, additionally thermal foam added,
• frame and sash thickness 98 mm,
• wood – joined pine, red Meranti,
• windowpane Ug = 0.6 of construction 4T/16Ar/4/16Ar/4T; windowpane packet up to 44 mm – limited by the sash weight that cannot exceed a bearing capacity of fittings,
• TPE sealing strip and sash rabbets,
• that allows obtaining the K coefficient for the whole window below 0.8 W/m2K,
ADPOL PASSIV
- K coefficient for a whole window below 0.8 W/m2K
• ADPOL PASSIV system of ADPOL 78 construction type,
• frame/sash of wooden construction: Red Meranti
• windowpane Ug = 0.4 of construction 4T/16Kr/4/14Kr/4T,
• ALURON aluminium drip edge - is different than a drip edge for windows in the A-68 system; the drip edge is identical for windows and balconies – screwed on to the bottom frame structure on the side,
• TPE sealing strip and sash rabbets,
• that allows obtaining the K coefficient for the whole window below 0.8 W/m2K,
• it is recommended to use the EPDM sealing strip in case of external windowsills,
| |